Standardization of a CT Protocol for Imaging Patients with Suspected COVID-19 : A RACOON Project

ORCID
0000-0001-6259-5765
Affiliation
Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany
Steuwe, Andrea;
ORCID
0000-0002-0518-5695
Affiliation
Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany
Kamp, Benedikt;
ORCID
0000-0002-6861-6245
Affiliation
Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany(J.B.)
Afat, Saif;
Affiliation
Clinic and Outpatient Clinic for Radiology, University Hospital Halle (Saale), 06120 Halle, Germany(A.G.)
Akinina, Alena;
ORCID
0000-0002-0822-9075
Affiliation
Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein Campus Kiel, 24105 Kiel, Germany
Aludin, Schekeb;
Affiliation
Department of Diagnostic and Interventional Radiology, University Hospital of Marburg, 35043 Marburg, Germany
Bas, Elif Gülsah;
ORCID
0009-0004-7149-0323
Affiliation
Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany(J.B.)
Berger, Josephine;
ORCID
0009-0008-6864-604X
Affiliation
Department of Diagnostic and Interventional Radiology, University Hospital Giessen, Justus Liebig University, Klinikstr. 33, 35392 Giessen, Germany
Bohrer, Evelyn;
ORCID
0000-0001-8033-6855
Affiliation
Department of Diagnostic and Interventional Radiology, University Hospital Giessen, Justus Liebig University, Klinikstr. 33, 35392 Giessen, Germany
Brose, Alexander;
Affiliation
Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany(C.K.)
Büttner, Susanne Martina;
Affiliation
Department of Diagnostic and Interventional Radiology, University of Leipzig Medical Center, Liebigstraße 20, 04103 Leipzig, Germany
Ehrengut, Constantin;
Affiliation
Clinic of Radiology, University of Münster, 48149 Münster, Germany
Gerwing, Mirjam;
ORCID
0000-0002-9093-6499
Affiliation
Department of Radiology, LMU University Hospital, LMU Munich, 81377 Munich, Germany
Grosu, Sergio;
ORCID
0000-0003-2300-4883
Affiliation
Clinic and Outpatient Clinic for Radiology, University Hospital Halle (Saale), 06120 Halle, Germany(A.G.)
Gussew, Alexander;
GND
1313252506
ORCID
0000-0002-4414-2188
Affiliation
Department of Radiology, Jena University Hospital, Friedrich Schiller University
Güttler, Felix;
GND
1223406903
ORCID
0000-0002-3862-4543
Affiliation
Department of Radiology, Jena University Hospital, Friedrich Schiller University
Heinrich, Andreas;
Affiliation
Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
Jiraskova, Petra;
Affiliation
Department of Diagnostic and Interventional Radiology, Ulm University Medical Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany(C.K.)
Kloth, Christopher;
ORCID
0000-0001-5021-6895
Affiliation
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
Kottlors, Jonathan;
Affiliation
Clinic of Radiology, University of Münster, 48149 Münster, Germany
Kuennemann, Marc-David;
Affiliation
Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstraße 2, 86156 Augsburg, Germany
Liska, Christian;
Affiliation
Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Stenglinstraße 2, 86156 Augsburg, Germany
Lubina, Nora;
ORCID
0009-0000-8464-6287
Affiliation
Institute of Diagnostic and Interventional Radiology, Paediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057 Rostock, Germany
Manzke, Mathias;
ORCID
0000-0002-3201-1033
Affiliation
Institute of Diagnostic and Interventional Radiology, Paediatric Radiology and Neuroradiology, University Medical Centre Rostock, Schillingallee 36, 18057 Rostock, Germany
Meinel, Felix G.;
ORCID
0000-0001-8489-706X
Affiliation
Department of Diagnostic and Interventional Radiology, University of Leipzig Medical Center, Liebigstraße 20, 04103 Leipzig, Germany
Meyer, Hans-Jonas;
ORCID
0000-0001-5743-473X
Affiliation
Department of Radiology, LMU University Hospital, LMU Munich, 81377 Munich, Germany
Mittermeier, Andreas;
Affiliation
Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
Persigehl, Thorsten;
ORCID
0000-0002-7746-5549
Affiliation
Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein Campus Kiel, 24105 Kiel, Germany
Schmill, Lars-Patrick;
ORCID
0009-0008-2478-5590
Affiliation
Institute of Diagnostic and Interventional Radiology, School of Medicine and Health, Technical University of Munich, 81675 Munich, Germany
Steinhardt, Manuel;
Affiliation
Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany
Antoch, Gerald;
Affiliation
Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany
Valentin, Birte

CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDI vol ), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kV p , with the majority between 100 and 120 kV p . CTDI vol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.

Cite

Citation style:
Could not load citation form.

Rights

License Holder: © 2024 by the authors.

Use and reproduction: