XUV Fluorescence Detection of Laser-Cooled Stored Relativistic Ions

Affiliation
Institute of Nuclear Physics, University of Münster, 48149 Münster, Germany
Ueberholz, Ken;
ORCID
0000-0003-3747-638X
Affiliation
GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany
Bozyk, Lars;
Affiliation
CASUS Görlitz, 02826 Görlitz, Germany
Bussmann, Michael;
Affiliation
Institute of Applied Physics, TU Darmstadt, 64289 Darmstadt, Germany
Eizenhöfer, Noah;
ORCID
0000-0002-2944-8373
Affiliation
Institute of Nuclear Physics, University of Münster, 48149 Münster, Germany
Hannen, Volker;
Affiliation
Institute of Nuclear Physics, TU Darmstadt, 64289 Darmstadt, Germany
Horst, Max;
Affiliation
Institute of Applied Physics, TU Darmstadt, 64289 Darmstadt, Germany
Kiefer, Daniel;
Affiliation
Institut für Dünne Schichten und Synchrotronstrahlung, University Kassel, 34127 Kassel, Germany
Kiefer, Nils;
Affiliation
GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany
Klammes, Sebastian;
Affiliation
GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany
Kühl, Thomas;
Affiliation
Institute of Applied Physics, TU Darmstadt, 64289 Darmstadt, Germany
Langfeld, Benedikt;
Affiliation
HZDR Dresden, Institut for Radiation Physics, 01328 Dresden, Germany
Loeser, Markus;
ORCID
0000-0001-9831-0565
Affiliation
IMP Lanzhou, Institute of Modern Physics, Lanzhou 730000, China
Ma, Xinwen;
ORCID
0000-0001-7432-3687
Affiliation
Institute of Nuclear Physics, TU Darmstadt, 64289 Darmstadt, Germany
Nörtershäuser, Wilfried;
Affiliation
GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany
Sánchez, Rodolfo;
ORCID
0000-0003-0390-7671
Affiliation
HZDR Dresden, Institut for Radiation Physics, 01328 Dresden, Germany
Schramm, Ulrich;
Affiliation
HZDR Dresden, Institut for Radiation Physics, 01328 Dresden, Germany
Siebold, Mathias;
Affiliation
GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany
Spiller, Peter;
Affiliation
GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany
Steck, Markus;
GND
1156630649
Affiliation
Institut für Optik und Quantenelektronik, Friedrich-Schiller-Universität Jena, 07743 Jena, Germany
Stöhlker, Thomas;
ORCID
0000-0001-8114-1785
Affiliation
Institute of Applied Physics, TU Darmstadt, 64289 Darmstadt, Germany
Walther, Thomas;
Affiliation
IMP Lanzhou, Institute of Modern Physics, Lanzhou 730000, China
Wang, Hanbing;
Affiliation
Institute of Nuclear Physics, University of Münster, 48149 Münster, Germany
Weinheimer, Christian;
ORCID
0000-0001-5266-3058
Affiliation
IMP Lanzhou, Institute of Modern Physics, Lanzhou 730000, China
Wen, Weiqiang;
Affiliation
GSI Helmholtzzentrum für Schwerionenforschung GmbH, 64291 Darmstadt, Germany
Winters, Danyal

An improved moveable in vacuo XUV fluorescence detection system was employed for the laser cooling of bunched relativistic ( β = 0.47) carbon ions at the Experimental Storage Ring (ESR) of GSI Helmholtzzentrum Darmstadt, Germany. Strongly Doppler boosted XUV fluorescence (∼90 nm) was emitted from the ions in a forward light cone after laser excitation of the 2s–2p transition (∼155 nm) by a new tunable pulsed UV laser system (257 nm). It was shown that the detected fluorescence strongly depends on the position of the detector around the bunched ion beam and on the delay (∼ns) between the ion bunches and the laser pulses. In addition, the fluorescence information could be directly combined with the revolution frequencies of the ions (and their longitudinal momentum spread), which were recorded using the Schottky resonator at the ESR. These fluorescence detection features are required for future laser cooling experiments at highly relativistic energies (up to γ ∼ 13) and high intensities (up to 10 11 particles) of ion beams in the new heavy ion synchrotron SIS100 at FAIR.

Cite

Citation style:
Could not load citation form.

Rights

License Holder: © 2023 by the authors.

Use and reproduction: