Intraoperative Fluoroscopy Allows the Reliable Assessment of Deformity Correction during Periacetabular Osteotomy

ORCID
0000-0002-4995-4951
Affiliation
Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Straße, 17475 Greifswald, Germany
Reichert, Johannes Christian;
Affiliation
Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Straße, 17475 Greifswald, Germany
Hofer, André;
GND
122932978
ORCID
0000-0002-5105-5875
Affiliation
Orthopaedic Department, Campus Eisenberg, University Hospital Jena
Matziolis, Georg;
Affiliation
Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Straße, 17475 Greifswald, Germany
Wassilew, Georgi Iwan

We aimed to determine the accuracy and reliability of measures characterizing anterior, lateral, and posterior acetabular coverage on intraoperative fluoroscopic images compared to postoperative radiographs when performing periacetabular osteotomies (PAOs). A study involving 100 PAOs was initiated applying a standardized intraoperative imaging protocol. Coverage was determined by the lateral center edge angle (LCEA), the Tönnis angle (TA), and the anterior and posterior wall index (AWI, PWI). An intraclass correlation coefficient (ICC) model was used to assess interrater (ICC (3,2)) and intrarater (ICC (2,1)) reliability. The ICC (2,2) between analyses obtained from intraoperative fluoroscopy and postoperative radiographs and the corresponding 95% confidence interval (CI) were determined and complemented by Bland–Altman analysis, the mean difference, and 95% limits of agreement (LOA). The ICCs were 0.849 for the LCEA (95% CI 0.783–0.896), 0.897 for the TA (95% CI 0.851–0.930), 0.864 for the AWI (95% CI 0.804–0.907), and 0.804 for the PWI (0.722–0.864). The assessed interrater reliability was excellent except for the AWI, which was graded good (ICC = 0.857, 95% CI 0.794–0.902). Interrater agreement was generally good and fair for the AWI (ICC = 0.715, 95% CI 0.603–0.780). For each postoperative radiograph, interrater reliability was good with ICCs ranging from 0.813 (TA) to 0.881 (PWI). Intrarater reliability was good for all measurements and excellent for the preoperative TA (ICC = 0.993, 95% CI 0.984–0.997) and PWI (ICC = 0.954, 95% CI 0.919–0.97). In summary, we confirm the validity and reliability of intraoperative fluoroscopy as an alternative imaging modality to radiography to evaluate acetabular fragment orientation during PAO. We affirm the LCEA and TA as precise measures for lateral head coverage, and show the suitability of the AWI and PWI to steadily assess acetabular version.

Cite

Citation style:
Could not load citation form.

Rights

License Holder: © 2022 by the authors.

Use and reproduction: